P. 4720. The operation of the demister is the following: a fan blows the air towards a cooled surface, and the condensed water vapour is collected in a container. How much heat is given off to the air in the room by the demister, rated at 180 W, in 15 hours, if it collected 4 litres of water? The temperature of the room is \(\displaystyle 25~{}^\circ\)C.

If the demister is considered to be a heat pump, what is its coefficient of performance (the ratio of the released heat to the electrical energy consumed)?

(4 points)

Deadline expired on 10 April 2015.


Statistics on problem P. 4720.
29 students sent a solution.
4 points:Fehér Balázs, Fekete Panna, Fülöp Erik, Németh 017 András, Olosz Balázs, Páhoki Tamás, Szentivánszki Soma , Szépfalvi Bálint.
3 points:Radnai Bálint.
2 points:19 students.
1 point:1 student.